BRMNZ - EXHAUST CARBON MONOXIDE (0-200 PPM) IN AIR

  • MSDS: BRMNZ
  • Manufacturer: GASTECH INC
  • Product Name: EXHAUST CARBON MONOXIDE (0-200 PPM) IN AIR
  • National Stock Number: 6830-00N039443
Product Identification

Product ID:EXHAUST CARBON MONOXIDE (0-200 PPM) IN AIR
MSDS Date:12/30/1992
FSC:6830
NIIN:00N039443
MSDS Number: BRMNZ

Responsible Party
GASTECH INC
8407 CENTRAL AVE
NEWARK, CA 94560-3431
US

Emergency Phone: 510-794-6200

Info Phone: 510-745-8700

Cage: DO808

Contractor
GASTECH INC
NEWARK, CA 94560-3431 US

Telephone: 510-794-6200

Cage: DO808

Ingredients

CARBON MONOXIDE

CAS: 630-08-0

RTECS: FG3500000

Fraction By Weight: <1%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM; 9293


AIR, REFRIGERATED LIQUID; AIR COMPRESSED (UN1002, DOT); AIR

RTECS: AX5271000

Fraction By Weight: 99.9%

OSHA PEL N/K

ACGIH TLV: N/K


AIR

CAS: 25635-88-5

Fraction By Weight: 99.9%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE LISTED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: HEADACHE, TACHYPNEA, NAUSEA,
WEAKNESS, DIZZINESS, CONFUSION, HALLUCINATIONS, CYANOSIS, ABNORMAL
ELECTROCARDIOGRAM, ANGINA, SYNCOPE. CHRONIC: SOME ACUTE EFFECTS
IDENTIFIED MAY BECOME CHRONIC.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:TARGET ORGANS: CARDIOVASCULAR SYSTEM, LUNGS,
BLOOD, CENTRAL NERVOUS SYSTEM.
Medical Cond Aggravated by Exposure:CHRONIC RESPIRATORY PROBLEMS,
CORONARY ARTERY DISEASE OR HEART DISEASE.

First Aid

First Aid:INHALATION: PROVIDE FRESH AIR OR OXYGEN AND CONSULT
PHYSICIAN. INGESTION: CALL MD IMMEDIATELY . EYE: FLUSH WITH WATER
FOR AT LEAST 15 MINUTES . SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER
(F P N).

Fire Fighting

Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:COMPRESSED GAS CYLINDERS MAY EXPLODE IN
HEAT OF FIRE. WITHDRAW IMMEDIATELY IN CASE OF RISING SOUND FROM
VENTING SAFETY DEVICE.

Accidental Release

Spill Release Procedures:EVACUATE AND VENTILATE AREA.
Neutralizing Agent:NONE LISTED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE SAFE HANDLING PRACTICES FOR
HANDLING OF COMPRESSED GAS CYLINDERS. DO NOT PUNCTURE. STORE IN
COOL, DRY AREA.
Other Precautions:USE SAFE STORAGE PRACTICES FOR STORAGE OF COMPRESSED
GAS CYLINDERS. EXPOSURE TO TEMPERATURES ABOVE 150F MAY OPERATE
EXCESS-PRESSURE VALVE.

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION SUFFICIENT TO KEEP AIRBORNE
CONCENTRATION BELOW CURRENT EXPOSURE LIMITS .
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL SAFETY GOGGLES .
Other Protective Equipment:NONE LISTED BY MANUFACTURER.
Work Hygienic Practices:NONE LISTED BY MANUFACTURER.
Supplemental Safety and Health
NONE LISTED BY MANUFACTURER.

Chemical Properties

Vapor Density:1.0
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS, ODORLESS GAS.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, BROMINE TRIFLUORIDE, CHLORINE TRIFLUORIDE, LITHIUM,
NICKEL, AND OIL IN HIGH PRESSURE EQUIPMENT.
Stability Condition to Avoid:NONE IDENTIFIED.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:EMPTY CONTAINERS MAY BE DISCARDED AS METAL
REFUSE, OBSERVING FEDERAL, STATE, AND LOCAL REGULATIONS. DO NOT
INCINERATE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.